  1. This paper analyses the load interrupting process of generator circuit breaker and the stress produced when interrupting. The definite formulations for calculating the RRRV and the testing methods for checking the capacity of load interrupting are presented the effective measures which can reduce the RRRV are proposed.
    分析发电机断路器的负荷开断过程及其产生的应力:并提出了计算RRRV的具体公式和校核负荷开断能力的试验方法以及降低RRRV的有效措施。
  2. The dynamic reactive power compensation as well as the load unbalances correction was implemented quickly by the synchronous switching of capacitor banks us-ing a phase control vacuum circuit breaker with permanent magnetic actuator.
    通过分相控制的永磁机构真空断路器同步投切电容器组实现对电力系统中无功功率的快速动态补偿,并校正负载不平衡。
  3. LAP-ⅱ-D electric power load control equipment is developed based on remote signaling and control technique, which realizes remote breaker switching and state monitoring.
    介绍了应用遥信技术功能开发LAP-Ⅱ-D型电力负荷控制装置,实现远方开关控制和开关状态监视。
  4. This paper mainly discusses the distributional characteristics of the breaker flow and the suspended load sediment in the coastal breaker area.
    本文主要讨论近岸破波区破波水流和悬移质泥沙分布特征。
  5. For increasing the interrupting capability at no load current, permanent magnetic field is drawn into the arc-rotated interrupter of sulfur hexafluoride ( SF 6) circuit breaker.
    为了增强开断空载电流的能力,在SF6断路器的旋弧式灭弧室中加入永久磁场。
  6. It is assumed that the load in every region is independent each other and the forecasted load is distributed in normal, thus the forecasted result related to the load passing through each circuit breaker and its probabilistic distribution can be further obtained.
    基于各个区域的负荷相互独立、负荷预测结果呈正态分布的假设,得出流过各个开关的负荷及其概率分布的预测结果。
  7. The controller used estimated rotor speed of machine as input and controlled an active load via breaker.
    该控制器利用发电机的转速作为输入来进行判断,通过断路器来控制有功负荷。
  8. Interrupting no load transformer is the most serious case in vacuum circuit breaker switching overvoltage.
    切除空载变压器是真空断路器操作过电压问题最严重的情况。
  9. It is possible that the cables at the load side of a circuit breaker can not get sufficient protection due to improper matching between the circuit breaker and the cables.
    针对配电线路中存在的由于负载侧电缆与保护断路器的配合不当,使得负载侧电缆得不到有效的保护,导致电缆绝缘层温升过高引发线路短路和漏电事故。
  10. There are 3 kinds of breakers at the generator outlet, including the load switch to cut off the load current, circuit breaker with limited breaking capacity and circuit breaker with full breaking capacity.
    发电机出口断开装置,分为仅能开断负荷电流的负荷开关、具有有限开断容量的断路器和具有全开断容量的断路器3种。
  11. Protection against motor over-load usually adopt thermal relay, but protection against line over-load usually adopt long delay over-current release of circuit-breaker.
    电动机过载保护通常采用继电器,而配电线路过载保护多采用断路器的长延时过电流脱扣器来完成。
  12. By the results of simulation, this paper summarized the measures for improving the reliability of distribution network, which include installation fuse in load branch line, adding circuit breaker, disconnector and backup appropriately.
    根据仿真计算的结果,总结了提高配电网可靠性的措施。在负荷分支线安装熔断器,增设断路器、隔离开关以及适当添加备用电源均可提高配电网的可靠性。